CONTENTSTART

24CGA6.2S: Gemini 6 convection steamer with gas generator

SHORT SERIES PRESSURELESS STEAMER, TWIN, INDEPENDENT GAS-FIRED GENERATORS

Cleveland  SteamCraft‚ Gemini Model 24CGA6.2S, 54.5" high, Two compartment steamer. Independent steam generators, 50,000 BTU's input per compartment. "SureCook" electro mechanical timer with load compensating feature. Gas valve and water level control system. Exclusive remote probe-type water level controls. Exclusive Brass “Steam Jet” distribution system. Two-piece free-floating compartment door. 14 gauge stainless steel cavity and door. Pullout service drawer for controls and Gemini Drain/Power Control System.

Macro Values (These are set programatically in the App_Code/Manitowoc/Classes/Manitowoc.cs under ProductHelpers.SetProductMacros()
ProductNodeAliasPath: /Products-Parts-and-Accessories/Products/Cleveland/Steamers/Convection-Models/24CGA6-2S-Gemini-6-convection-steamer-with-gas-ge
ValidVariantIDs: 47695
ValidSkuIDs: 47700
DocAssetList: uihlu|wzcps|vqjfc|ldtxd|yfsbp|tzrpb|jwmtg
ImgAssetList: xgkqcj
VidAssetList: nsaab
Features: /Products-Parts-and-Accessories/Products/Cleveland/Steamers/Convection-Models/24CGA6-2S-Gemini-6-convection-steamer-with-gas-ge/%
Categories: steamers
Attributes: 6pans|cooktech-convection
Brands: cle
Related Products:
Related Variants:
Related Skus:
DisplayFeatures: True
DisplayTechSpecs: True
DisplayAccessories: True
  • Capacity
    • Each compartment has cooking capacity for 5 each 12" x 20" x 2 1/2" Steam Table Pans
  • Cleaning Light
    • Light for each compartment warns the operator to delime generator
  • Controls
    • Each compartment has one, 60-Minute Electro-Mechanical Timer with "SureCook" load compensating feature. Manual Bypass Switch for constant steaming.
  • Door
    • Durable 14 Gauge, 304 Stainless Steel construction for compartment door, cooking cavity and steam generator
  • Door Hinging
    • Doors hinged left and the controls on the right
  • Easy Access Cleaning Port
    • Each generator has a deliming port located on the outside, top of the unit
  • Exclusive Control System
    • Manual 1/2 inch "Ball Valve" type drain that controls main power On/Off and automatically fills generator (located on the control panel)
  • Front -Access Servicing
    • Easy, Front -Access Generator Controls comes with a pullout drawer for simple servicing of unit
  • Generator
    • High efficiency independent Power Burner Steam Generators 50,000 BTU's for each compartment
  • Independant Compartments
    • Each steam-cooking compartment is independently operated and controlled by a separate stainless steel steam generator, gas valve, Power On/Off Control Levers and a Exclusive, Remote Probe-Type Water Level Control
  • Legs
    • 6" Stainless Steel Adjustable Legs with Flanged Feet
  • Safety Switch
    • Compartment Steam Shut-Off Switch when compartment door is opened
  • Short Series
    • 54.5" (1385mm) height to top of upper compartment (lower height makes maintenance easier by lowering the descaling ports)
  • Standby Mode
    • Holds generator at a steaming temperature, allows unit to start cooking quickly
  • Steam Jets
    • Exclusive Brass Steam Jets distribute steam even throughout cooking compartment
Gemini 6, Model 24CGA6.2S with Gas Generator
W x D x H 24" x 331/2" x 591/2"
61cm x 85.1cm x 151.1cm
Weight 565 lb
256.3 kg
Power Output 50000.00 N/A
Power Input Type Gas - Natural
Primary Power Input 115-120 V x 60 Hz x 1 PH
Certifications AGACGACSAENERGY STARNSFULWelbilt Enerlogic
Cafeteria Pans
In depths of 1", 2 1/2" and 4"
Dissolve Descale Solution
6 one gallon container w/quart markings (106174)
Electronic Timer
With Compensating Load Feature (ETC)
ON/OFF Steam Switch
For compartment controls (MC)
Propane Gas
(PG)
Water Filters
Replacement cartridges available

Brochure & Sell Sheets

Gemini 10 Brochure

CAD Symbols (KCL Cutsheets)

AutoCAD Drawings

Owner Instruction Manual

SteamCraft Ultra 5, Ultra 10, Gas

Menu or Recipe Guide

Convection Steamer Cookbook

Parts Catalog List

24CGA6.2 Parts Manual

Service Manual

24CGA6.2 Sequence of Operation, Schematics and Troubleshooting

Specification Sheets

SteamCraft Gemini 6

CONTENTEND

Convotherm Software Updates

We are pleased to provide you the latest software updates of the Convotherm range.

Please just agree our terms and conditions of licence and use for using the software.

I noticed the terms and conditions of licence and agree


Please note:

The particular software update for Convotherm 4 gas units has to be done by an authorised service partner (there are adjustment steps necessary).

Please ensure that only software which is suitable for the unit series is installed on your Convotherm unit. This software cannot be used for other unit types from the range. If this is disregarded, no liability will be assumed for malfunctions.

Convotherm Service manuals

This section is available for authorized service partner only.

Some files are protected with a password. If you need the password please get in contact with our After Sales Service: con.kundendienst@manitowoc.com

We use cookies to ensure you get the best user experience and to continuously improve our website. Learn more
ACKNOWLEDGED